RV Tankless Water Heater Repair in Apopka, FL

RV Repair Apopka repairs RV tankless water heaters throughout Orange, Seminole, and Volusia counties. Rinnai and Girard tankless water heaters - no hot water, ignition failure, low flow issues. We diagnose and repair on-site. Call (407) 326-5500.

RV tankless water heaters provide unlimited hot water but are more sensitive to water quality and flow rate than tank heaters. Florida campground water often contains sand and mineral sediment that clogs the inlet strainer on tankless units - the most common cause of 'no hot water' on a tankless unit is actually a blocked inlet, not a heater failure.

The Rinnai and Girard tankless units used in RVs have very specific minimum flow requirements - typically 0.5 to 0.7 gallons per minute to trigger the flow sensor and start the burner. If water pressure or flow is too low (from a partially closed valve, clogged strainer, or weak pump), the heater won't activate even though everything else is working.

Tankless Water Heater Diagnosis

Common Tankless RV Repairs

Inlet strainer cleaning is a 20-minute fix that resolves 30 to 40 percent of tankless 'no hot water' calls. The strainer is at the cold water inlet and is easily accessed from the exterior compartment. For flow sensor failures, the sensor is replaceable on-site. Control board failures are the most expensive repair on tankless units and sometimes make replacement more cost-effective on older units.

Service area: Apopka, Longwood, Casselberry, Altamonte Springs, Sanford, Lake Mary, DeLand, Deltona, DeBary, Mount Dora, Tavares, Leesburg, and all surrounding communities in Orange, Seminole, Lake, and Volusia counties.

Pricing for RV Tankless Water Heater Repair

Starting price range: $95 - $485. Flat-rate quote provided before any work begins. Request a free quote online or call (407) 326-5500.

*Estimates only. Final price determined on-site after diagnosis. Parts and labor included in flat rate.

Related Services

Also see: All RV Water Heater Repair services | All RV Repair Services | Apopka Service Area

FAQ

Common Questions

Low campground water pressure or a pressure regulator set too low can reduce flow below the 0.5 GPM minimum the unit needs to activate. Try running the hot water without the pressure regulator temporarily to test if flow rate is the issue.

Shut off the water supply, remove the small screen filter at the cold water inlet connection (usually a 3/4 inch fitting), rinse the screen under running water to remove sediment, and reinstall. Do this annually or after campgrounds with visibly sandy or dirty water.

The Girard GSWH series shows error codes on a small LED or display. Common codes: E1 = ignition failure, E2 = overheating/thermal cutout, E3 = flow sensor issue. Share the code when you call and we'll diagnose before arriving.

If the unit is under 7 years old and the repair is a flow sensor or control board, repair is typically worth it. Older units with multiple failed components often make more sense to replace with a current Rinnai or Girard model.

Book Your RV Tankless Water Heater Repair Today

Mobile service in Apopka and surrounding areas. Flat-rate pricing, no towing fees, same-day availability.